ATS Scheme




The degradation of test detectors at the ATS is being carried out under sustained irradiation by the 90Sr (2 Ci) b-source irradiation.




The measurements of the detectors properties (gas gain, dark current, count rate) are being performed regularly during the test. To monitor the gas gain, the peak position of the pulse-height distribution from the 55Fe X-ray source is controlled.





The scheme of the readout electronics used for the monitoring is shown below.
ATS Readout




Signals from the tested wires are fed to preamplifier (PA) mounted on the detector sensitve wire. The PA's non-linearity is less of 1%. The signal coming from the wire is integrated with t = 1 msec by the specrometrical shaper and then passes to the 12 bit Analog/Digital Converter (ADC). The data obtained from ADC is analysed and plotted with PC.