SUPRA SUPRAFAX v.32bis
Manufacturer: Supra
Model: SupraFAX v.32bis
Latest Firmware Revision Tried: V1.200-H TR14-Jxxx-001
Recommended Firmware Revisions: V1.200-H TR14-Jxxx-001
Last Updated:$Date: 1995/04/04 17:45:59 $
-
- Supra provides
documentation on the Class 1 programming interface.
-
- Supra provides
documentation on the Class 2 programming interface.
-
- Firmware rev V1.80-02 TR14-Jxxx-001 is a significant improvement over
previous firmware; it is highly recommended that you upgrade your modem
if you have older firmware.
CLASS 1 SUPPORT
- The AT+FAE
command that can be used to enable auto-detect of calls from
data modems is only accepted in Class 0 (data mode); I've never been
able to get it to work correctly (when setup the modem is either unable
to establish carrier, or the modem locks up after notifying the host)
- RTS/CTS is not honored while sending/receiving page data; use AT&K4
for software (XON/XOFF) flow control
CLASS 2 SUPPORT
- Changing DCD handling can cause the modem to drop DSR; if done
during initialization this can cause the fax server to get confused;
be sure that the setting loaded from NVRAM on reset agrees with
the value specified in the config file (AT&C1 by default); one
possible way of doing this is to specify &F2 for the ModemResetCmds
parameter
- The line counts in the +FPTS result code during a reception are
total nonsense; the only way to deduce the number of lines in a
received page of data is to parse the data on the host
- Facsimile reception is locked at 19200 baud
- Adaptive answer is not reliable
- The training algorithm can loop forever; client software must
timeout AT+FDR requests
(fixed in rev V1.80-02 TR14-Jxxx-001)
- RTS/CTS is not honored while receiving page data
- The firmware often responds incorrectly to an EOM post-page message;
the modem has been observed to drop carrier and/or respond with an
incorrect HDLC message
Telebit WorldBlazer/T3000